FMGCG
Oil And Flame Retardant Rubber
Insulation Communication and
Signal Cables
Oil And Flame Retardant Rubber
Insulation Communication and
Signal Cables
Conductor
Stranded tinned copper wire
IEC 60228 class 2
Insulation
EPRrubbercompound
Laid Up
Cores laid up in pairs, pairs laid up concentrically
Separating Foil
Over cable core, foil
Screen
Copper braided screen
Separating Oil
Above braided screen, foil
Outer Sheath
Chloroprene based flame retardant and oil resistant outer jacket.
The cable is used above and below deck of the ship as control and communication cables in radio, radar and information systems.
Related Standard | DIN 89159 (IEC 60092/375, 376) |
Test and Material | IEC 60092/350-351 -359 |
Flame Retardant | IEC 60332/1 IEC 60332/3A |
Working Temp | + 85°C |
Min.bending Radius | 8*cable dia. (mm) |
Rated Voltage | 60-250V |
Test Voltage | 1,5 kV |