FMGCH- FFR

Halogen Free Fire Resistant Ship &

Offshore Communication and

Signal Cables

Product Info

Product Description

Cable Structure

Conductor

Stranded copper wire
IEC 60228 class 2

Insulation

MICA TAPE + EPR compound

Laid Up

Cores laid up in pairs, pairs laid up concentrically

Separating Oil

Over cable core, foil

Screen

Electrolytic plain copper braided screen

Separating Foil

Above braided screen, foil

Outer Sheath
Halogen- free, flame retardant thermoplastic polyolefin based compound (HM41SHF 1 ) – HD 604 – IEC
332 / 3 green

Application

The cable is used above and below deck of the ship as control and communication cables in radio, radar  and information systems

Halogen-free cables with enhanced characteristic

in case of fire are used for application where harm to human life and damage to property must be prevented in the event of a fire.

Production and Test Standards
Construction DIN 89159 (IEC 600921375,376)
Test and Material IEC 60092 /350-351 -359
Fire and Flame Retardant IEC 60331
IEC 6033211
IEC 60332 / 3A
Halogen, Gas Content IEC 60754 I 1-2
Perm, Working Temp + 85°C
Min.bending Radius 8 cable dia. (mm)
Rated Voltage 60-250V
Test Voltage 1,5 kV