Shore

Shore Power Cables

Product Info

Product Description

Cable Structure

Conductor

Electrolytic standard copper wire
IEC 60228 class 2

Insulation

Special polyurethane compound or
PVC compound

Inner Sheath

Rubber based compound or
PVC compound

Outer Sheath

Special polyurethane compound yellow

Application

They are used as shore connection power cable. They are very resistant to all conditions in the marine environment.

Production and Test Standards
Related Standard IEC 60502/1
IEC 60092/353-350
Perm, Working Temp – 35°C/ + 90°C
Min.bending Radius 8*cable dia. (mm) fixed
Rated Voltage 0.6/1 kV
Test Voltage 3,5 kV