FM2XCH- FFR

Halogen Free Fire Resistant Ship

and Offshore Communication

and Signal Cables

Product Info

Product Description

Cable Structure

Conductor

Stranded copper wire
IEC 60228 class 2

Insulation

MICA TAPE + XLPE compound

Laid Up

Cores laid up in pairs, pairs laid up concentrically

Separating Oil

Over cable core, foil

Screen

Electrolytic plain copper braided screen

Separating Oil

Above braided screen, foil

Outer Sheath

Halogen-free, flame retardant thermoplastic polyolefin-based compound (HM41SHF 1) – HD 604 – IEC
332 I 3 green

Application

The cable is used above and below deck of the ship as control and communication cables in radio, radar and information systems

Halogen-free cables with the enhanced characteristic in case of fire are used for application where harm to human life and damage to property must be prevented in the event of a fire.

Production and Test Standards
Construction IEC 600921375,376
Test and Material IEC 600921375,376
Fire and Flame Retardant IEC 60331
IEC 6Retardant:
IEC 60332 I 3A
Halogen, Gas Content IEC 60754 I 1 – 2
Measur. Of Smoke Densily IEC 60754 I 1 – 2
Perm, Working Temp + 85°C
Min.bending Radius 8 cable dia. (mm)
Rated Voltage 250V
Test Voltage 1,5 kV