Conductor
Stranded copper wire
IEC 60228 class 2
Insulation
MICA TAPE + XLPE compound
Laid Up
Cores laid up in pairs, pairs laid up concentrically
Separating Oil
Over cable core, foil
Screen
Electrolytic plain copper braided screen
Separating Oil
Above braided screen, foil
Outer Sheath
Halogen-free, flame retardant thermoplastic polyolefin-based compound (HM41SHF 1) – HD 604 – IEC
332 I 3 green
The cable is used above and below deck of the ship as control and communication cables in radio, radar and information systems
Halogen-free cables with the enhanced characteristic in case of fire are used for application where harm to human life and damage to property must be prevented in the event of a fire.
Construction | IEC 600921375,376 |
Test and Material | IEC 600921375,376 |
Fire and Flame Retardant | IEC 60331 IEC 6Retardant: IEC 60332 I 3A |
Halogen, Gas Content | IEC 60754 I 1 – 2 |
Measur. Of Smoke Densily | IEC 60754 I 1 – 2 |
Perm, Working Temp | + 85°C |
Min.bending Radius | 8 cable dia. (mm) |
Rated Voltage | 250V |
Test Voltage | 1,5 kV |