FMGCH

Halogen Free Flame Retardant

Ship & Offshore Communication

and Signal Cables

Product Info

Product Description

Cable Structure

Conductor

Stranded copper wire
IEC 60228 class 2

Insulation

EPR compound

Laid Up

Cores laid up in pairs, pairs laid up concentrically

Separating Foil

Under screen, foil

Screen

Electrolytic plain copper braided screen

Separating Foil

Above screen, foil

Outer Sheath
Halogen- free, flame retardant thermoplastic polyolefin based compound (HM41SHF 1) – HD 604 – IEC 332 I 3
Black or grey

Application

The cable is used above and below deck of the ship as control and communication cables in radio, radar and information systems Halogen-free cables with an enhanced characteristic in case of fire are used for application where harm to human life and damage to property must be prevented in the event of a fire.

Production and Test Standards
Construction DIN 89159 (IEC 600921375)
Test and Material IEC 60092 /350-351 -359
Flame Retardant IEC 60332 11
IEC 60332 / 3A
Halogen, Gas Content IEC 60754 I 1-2
Measur. Of Smoke Densily IEC 61034 I 1-2 (DIN EN 5026811-2)
Perm, Working Temp + 85°C
Min.bending Radius 8 cable dia. (mm)
Rated Voltage 60-250V
Test Voltage 1,5 kV