MGCH & MGCH – EMC

Halogen Free Flame Retardant Ship

and Offshore Power Cables

Product Info

Product Description

Cable Structure

Conductor

Stranded annealed copper wire
IEC 60228 class 2

Insulation

EPR compound

Bedding

Halogen-free bedding compound

Screen

Electrolytic plain copper braided screen
(EMC) = %100 wrapped electrolytic copper tape

Outer Sheath

Halogen-free, flame retardant
thermoplastic polyolefin-based compound
(HM41SHF1) – HD 604 – IEC 332 I 3
Black or grey

Application

These cables are mainly used in permanent installations In ships. As a result of the materials used In the production, they are resistant to all the conditions in the marine environment such as dry wet and oil. Since they are screened by copper wire braided they prevent interference by radio and electronic equipment. Halogen-free cables with the enhanced characteristic in case of flreare used for application where harm to human life and damage to property must be prevented in the event of a fire.

Production and Test Standards
Construction DIN 89158 (IEC 600921353)
Test and Material IEC 600921
350-351-359
Flame Retardant IEC 60332 / 1
IEC 60332 / 3A
Halogen, Gas Content IEC 60754 I 1 – 2
Measur. Of Smoke Density IEC 61034 I 1 – 2 (DIN EN 50268/1-2)
Perm, Working Temp + 85°C
Min.bending Radius 8*cable dia. (mm) fixed
Rated Voltage 0.6/1 kV
Test Voltage 3,5 kV